Remote-processing CX-10 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Computadores Remote-processing CX-10. Remote Processing CX-10 User Manual Manual do Utilizador

CX-10 USER'S MANUAL

REV 1

Page i
Copyright 2009 - Remote Processing Corporation. All
rights reserved. However, any part of this document may
be reproduced with Remote Processing cited as the
source.
The contents of this manual and the specifications herein
may change without notice.

TRADEMARKS

Intel is a copyright of Intel Corporation.
Windows, Windows XP, and Windows Terminal are
trademarks of Microsoft Corporation.
Remote Processing is a registered trademark of Remote
Processing Corporation.
Remote Processing® Corporation
7975 E. Harvard Ave.
Denver, Co 80231 USA
Tel: (303) 690 - 1588
Fax: (303) 690 - 1875
internet: www.rp3.com

NOTICE TO USER

The information contained in this manual is believed to
be correct. However, Remote Processing assumes no
responsibility for any of the software or circuits
described herein, conveys no license under any patent or
other right, and make no representations that the circuits
are free from patent infringement. Remote Processing
makes no representation or warranty that such
applications will be suitable for the use specified without
further testing or modification. The user must make the
final determination as to fitness for a particular use.
Remote Processing Corporation's general policy does not
recommend the use of its products in life support
applications where the failure or malfunction of a
component may directly threaten life or injury. It is a
Condition of Sale that the user of Remote Processing
products in life support applications assumes all the risk
of such use and indemnifies Remote Processing against
all damages.

FCC NOTICE

The CX-10 was not tested for EMI radiation. When
operated outside a suitable enclosure, the board and any
cables coming from the board will radiate harmful
signals which interfere with consumer and industrial
radio frequencies. It is your responsibility to properly
shield the CX-10 and cables coming from it to prevent
such interference.
P/N 2XXX
Revision: 1.0

Ficheiro PDF · ·

Imprimir

Imprimir documento

Partilha

Resumo do Conteúdo

Página 1 - FCC NOTICE

CX-10 USER'S MANUAL REV 1 Page i Copyright 2009 - Remote Processing Corporation. All rights reserved. However, any part of this document may be…

Página 2 - TABLE OF CONTENTS

TABLE OF CONTENTS Page ii OVERVIEW SECTION 1 MANUAL ORGANIZATION 1 MANUAL CONVENTIONS 1 BASIC Statement types 1 Number convention 2 Terminology 2…

Página 3

DESCRIPTION OVERVIEW SECTION 1 The CX-10 is a intelligent IO controller programmable in BASIC and controlled using modbus. The BASIC is a variation of…

Página 4

specified events to happen. For the most part, multi- tasking must be set up in the program. Set up consists of a ON multi-tasking, parameters…

Página 5

Figure 1-1 CX-10 Outline Figure 1-2

Página 6 - INITIAL SETUP

Figure 2-1 Power and serial connection INTRODUCTION SETUP AND OPERATION SECTION 2 The CX-10 is ready to operate over modbus as soon as you connect it…

Página 7 - MODBUS OPERATION

two ways to do this: Through the programming port or the modbus port. Using the programming port means accessing the Basic operating system. You will…

Página 8

Figure 2-2 Initial Project 3 Screen

Página 9

Figure 2-3 Communications Setup Next step is to set the communication port to match your PC. See “Communication Setup” above to help determine what…

Página 10

Figure 2-4 Project 3 Modbus Data and Transaction initiation. Now click on the “Site Service” tab at the top left of the program. If not already done…

Página 11 - PROGRAMS

# of Regs. 1 On the right center of the program, under “Data”,click in the white area of “Reg 10" box. Enter a 7. Click on the green “Write (Func 16)”…

Página 12

Uploading programs is simply a process of receiving an ASCII file. You or your program simply need to send "LIST" to receive the entire program.…

Página 13

Demo directory is an example of automated download process. This program clears out the old program and prepares for a new one. Programming Commands…

Página 14 - TROUBLESHOOTING

To retrieve a program, type ROMx, where ‘x’ is the number of the progam. In the above example, that would be 1. Command Description FPROG0 Erases all…

Página 15

The CX-10 CPU will function down to around 3 volts. However any modbus communication may not work and relays may not turn on. Board operation when its…

Página 16 - DATA REGISTERS

SAVING DATA TO REGISTERS SECTION 3 Page 3-1 INTRODUCTION SAVING DATA TO REGISTERS SECTION 3 There are 2 numerical formats data can be saved as…

Página 17 - COMMANDS

SAVING DATA TO REGISTERS SECTION 3 Page 3-2 COMMANDS The following is a list of Basic commands used to read integer and floating point data. Command…

Página 18

Figure 4-1 Serial Port Locations DESCRIPTION SERIAL PORTS SECTION 4 The CX-10 has two serial ports that interface to a variety of devices. In…

Página 19

COM0 SERIAL PORT This port at J1 uses a VTC-9F serial cable to connect external serial devices to the port. The cable consists of a 10 pin IDC…

Página 20

CX-10 no RF modem Modbus Master RS-232 or RS-485 Figure 4-2 Basic Connection Modbus Master RS-485 Additional CX-10 or modbus device CX-10 no RF modem…

Página 21 - Modbus Slaves

CX-10 with RF modem RS-232 or RS-485 Modbus Master & slaves CX-10 with RF modem RF Link Additional CX-10 with RF modem Modbus Slaves Figure 4-4 CX-10…

Página 22

Modbus Master RS-485 Additional CX-10 or modbus device CX-10 with RF modem RS-485 RS-232 Optional CX-10 or other modbus devices Figure 4-5 Multiple…

Página 23

RADIO MODEM Using radio modems in a network is similar to using RS- 485 in a network. The only real difference is the modem connects to the CX-10…

Página 24

Figure 4-6 Serial port pinout (Top view) COMMANDS & REGISTERS The following is a list of Baisic commands and registers used for serial I/O. Register…

Página 25 - WATCHDOG SECTION 5

WATCHDOG SECTION 5 Page 5-1 INTRODUCTION WATCHDOG SECTION 5 The CX-10 watchdog timer may be used to reset the CPU should modbus communication or…

Página 26 - RELAY OPERATION

Relay 7 Relay 8 A B C P2 Figure 6-1 Relay group 1designations Relay 5 Relay 6 D E F P1 Figure 6-2 Relay group 2 designations INTRODUCTION RELAY AND…

Página 27

Relay 3Relay 4 G Relay 2 H K P1 M CommonRelay 1 L Figure 6-3 Relays group 3 designations Figure 6-4 Opto Buffered inputs and Relay Groups The third…

Página 28

Modbus Register Interface There are two ways relays can be controlled and status read: First is as a group through register 10. This is a bit mapped…

Página 29

Opto Buffered Inputs Opto inputs are designated on the CX-10 board as IN1- IN8. Common grounds are available on P2 and P4. See Figure 6-4 above for…

Página 30 - PULSE COUNTERS SECTION 7

PULSE COUNTERS SECTION 7 Page 7-5 INTRODUCTION PULSE COUNTERS SECTION 7 Two high speed (3000 pulses/second, 180,000 pulses/minute) counters are…

Mostrar as 44 páginas
Página 31 - POWER CONNECTIONS

INTRODUCTION BATTERY CHARGER & POWER SECTION 8 The CX-10 requires a minimum of 12 volts to operate. Power may be from a line powered DC supply (1…

Página 32 - POWER CONSUMPTION

Figure 8-1 Serial pinout (top view) Additionally, unswitched +5V is available at pin 10 on each serial connector. Fused battery power (12V) is…

Página 33 - APPLICATION PROGRAMS

Figure 8-1 Power IO Solar power requirements are more complex to determine. Power requirements depend upon estimated time relays will be on, how many…

Página 34

CPU Atmel AT80C51RE2 TECHNICAL SPECIFICATIONS SECTION 9 Power Supply Inputs: 12V minimum at “battery”. 0-25V at External power with 12V battery.…

Página 35 - MECHANICAL

CONNECTOR PINOUTS Four primary connectors are along one edge of the board. A couple of the connectors are multi-use while others are dedicated to one…

Página 36 - 4.050"

75" Holes in corners are 0.25" from each edge. 4.050" 0.750" 3.45" Figure 9-2 Mounting hole locations

Página 37

CX-10 Modbus Map Appendix A The following is the Modbus Register map for the CX-10. Register Groups Description Start Register End Register Type…

Página 38

Hardware I/O Registers. These are all integer (16 bit) types. Function code 3 reads, 16 writes. Register Read/write permission Detail 1 Read only Opto…

Página 39

Watchdog Timer These are all integer (16 bit) types. Function code 3 reads, 16 writes. Register Read/Write Permission Detail 30 Read or write Watchdog…

Página 40

Volatile Operating System These are integer (16 bit) types. Function code 3 reads, 16 writes. Not all registers allow read, write, or read and write.…

Página 41

Register 4783 operating detail Data returned from this register depends upon the CX-10 master/slave status at the moment. By default, the CX-10 is in…

Página 42

The format for function code 3(master mode request data) is: PRINT #3,id,3,address,length Where: id = modbus id of device requesting data from address…

Página 43

Non-Volatile Setup These are integer (16 bit) types. Function code 3 reads, 16 writes. All allow read and write. Address range is 4801 to 4999. This…

Página 44

Register Read/Write Permission Detail Appendix A Modbus Map Page 11 4824 Read or write Reserved, unused 4825 Read or write RF modem shutdown 1 =…