Remote-processing CX-10 Manual do Utilizador
Consulte online ou descarregue Manual do Utilizador para Computadores Remote-processing CX-10. Remote Processing CX-10 User Manual Manual do Utilizador
CX-10 USER'S MANUAL
REV 1
TRADEMARKS
NOTICE TO USER
FCC NOTICE
Ficheiro PDF · ·
Resumo do Conteúdo
CX-10 USER'S MANUAL REV 1 Page i Copyright 2009 - Remote Processing Corporation. All rights reserved. However, any part of this document may be…
TABLE OF CONTENTS Page ii OVERVIEW SECTION 1 MANUAL ORGANIZATION 1 MANUAL CONVENTIONS 1 BASIC Statement types 1 Number convention 2 Terminology 2…
DESCRIPTION OVERVIEW SECTION 1 The CX-10 is a intelligent IO controller programmable in BASIC and controlled using modbus. The BASIC is a variation of…
specified events to happen. For the most part, multi- tasking must be set up in the program. Set up consists of a ON multi-tasking, parameters…
Figure 1-1 CX-10 Outline Figure 1-2
Figure 2-1 Power and serial connection INTRODUCTION SETUP AND OPERATION SECTION 2 The CX-10 is ready to operate over modbus as soon as you connect it…
two ways to do this: Through the programming port or the modbus port. Using the programming port means accessing the Basic operating system. You will…
Figure 2-2 Initial Project 3 Screen
Figure 2-3 Communications Setup Next step is to set the communication port to match your PC. See “Communication Setup” above to help determine what…
Figure 2-4 Project 3 Modbus Data and Transaction initiation. Now click on the “Site Service” tab at the top left of the program. If not already done…
# of Regs. 1 On the right center of the program, under “Data”,click in the white area of “Reg 10" box. Enter a 7. Click on the green “Write (Func 16)”…
Uploading programs is simply a process of receiving an ASCII file. You or your program simply need to send "LIST" to receive the entire program.…
Demo directory is an example of automated download process. This program clears out the old program and prepares for a new one. Programming Commands…
To retrieve a program, type ROMx, where ‘x’ is the number of the progam. In the above example, that would be 1. Command Description FPROG0 Erases all…
The CX-10 CPU will function down to around 3 volts. However any modbus communication may not work and relays may not turn on. Board operation when its…
SAVING DATA TO REGISTERS SECTION 3 Page 3-1 INTRODUCTION SAVING DATA TO REGISTERS SECTION 3 There are 2 numerical formats data can be saved as…
SAVING DATA TO REGISTERS SECTION 3 Page 3-2 COMMANDS The following is a list of Basic commands used to read integer and floating point data. Command…
Figure 4-1 Serial Port Locations DESCRIPTION SERIAL PORTS SECTION 4 The CX-10 has two serial ports that interface to a variety of devices. In…
COM0 SERIAL PORT This port at J1 uses a VTC-9F serial cable to connect external serial devices to the port. The cable consists of a 10 pin IDC…
CX-10 no RF modem Modbus Master RS-232 or RS-485 Figure 4-2 Basic Connection Modbus Master RS-485 Additional CX-10 or modbus device CX-10 no RF modem…
CX-10 with RF modem RS-232 or RS-485 Modbus Master & slaves CX-10 with RF modem RF Link Additional CX-10 with RF modem Modbus Slaves Figure 4-4 CX-10…
Modbus Master RS-485 Additional CX-10 or modbus device CX-10 with RF modem RS-485 RS-232 Optional CX-10 or other modbus devices Figure 4-5 Multiple…
RADIO MODEM Using radio modems in a network is similar to using RS- 485 in a network. The only real difference is the modem connects to the CX-10…
Figure 4-6 Serial port pinout (Top view) COMMANDS & REGISTERS The following is a list of Baisic commands and registers used for serial I/O. Register…
WATCHDOG SECTION 5 Page 5-1 INTRODUCTION WATCHDOG SECTION 5 The CX-10 watchdog timer may be used to reset the CPU should modbus communication or…
Relay 7 Relay 8 A B C P2 Figure 6-1 Relay group 1designations Relay 5 Relay 6 D E F P1 Figure 6-2 Relay group 2 designations INTRODUCTION RELAY AND…
Relay 3Relay 4 G Relay 2 H K P1 M CommonRelay 1 L Figure 6-3 Relays group 3 designations Figure 6-4 Opto Buffered inputs and Relay Groups The third…
Modbus Register Interface There are two ways relays can be controlled and status read: First is as a group through register 10. This is a bit mapped…
Opto Buffered Inputs Opto inputs are designated on the CX-10 board as IN1- IN8. Common grounds are available on P2 and P4. See Figure 6-4 above for…
PULSE COUNTERS SECTION 7 Page 7-5 INTRODUCTION PULSE COUNTERS SECTION 7 Two high speed (3000 pulses/second, 180,000 pulses/minute) counters are…
Mostrar as 44 páginas
INTRODUCTION BATTERY CHARGER & POWER SECTION 8 The CX-10 requires a minimum of 12 volts to operate. Power may be from a line powered DC supply (1…
Figure 8-1 Serial pinout (top view) Additionally, unswitched +5V is available at pin 10 on each serial connector. Fused battery power (12V) is…
Figure 8-1 Power IO Solar power requirements are more complex to determine. Power requirements depend upon estimated time relays will be on, how many…
CPU Atmel AT80C51RE2 TECHNICAL SPECIFICATIONS SECTION 9 Power Supply Inputs: 12V minimum at “battery”. 0-25V at External power with 12V battery.…
CONNECTOR PINOUTS Four primary connectors are along one edge of the board. A couple of the connectors are multi-use while others are dedicated to one…
75" Holes in corners are 0.25" from each edge. 4.050" 0.750" 3.45" Figure 9-2 Mounting hole locations
CX-10 Modbus Map Appendix A The following is the Modbus Register map for the CX-10. Register Groups Description Start Register End Register Type…
Hardware I/O Registers. These are all integer (16 bit) types. Function code 3 reads, 16 writes. Register Read/write permission Detail 1 Read only Opto…
Watchdog Timer These are all integer (16 bit) types. Function code 3 reads, 16 writes. Register Read/Write Permission Detail 30 Read or write Watchdog…
Volatile Operating System These are integer (16 bit) types. Function code 3 reads, 16 writes. Not all registers allow read, write, or read and write.…
Register 4783 operating detail Data returned from this register depends upon the CX-10 master/slave status at the moment. By default, the CX-10 is in…
The format for function code 3(master mode request data) is: PRINT #3,id,3,address,length Where: id = modbus id of device requesting data from address…
Non-Volatile Setup These are integer (16 bit) types. Function code 3 reads, 16 writes. All allow read and write. Address range is 4801 to 4999. This…
Register Read/Write Permission Detail Appendix A Modbus Map Page 11 4824 Read or write Reserved, unused 4825 Read or write RF modem shutdown 1 =…
Perguntas sobre Remote-processing CX-10
Ainda não há perguntas sobre este manual. Faça a primeira.
Manuais e produtos relacionados com Computadores Remote-processing CX-10
- Computadores Remote-processing RPC-330 Manual do Utilizador
(48 páginas) - Computadores Remote-processing RPC-210 Manual do Utilizador
(60 páginas) - Computadores Remote-processing RPC-2300 Manual do Utilizador
(36 páginas) - Computadores Remote-processing RPC-52 Manual do Utilizador
(36 páginas) - Computadores Remote-processing RPC-30 Manual do Utilizador
(38 páginas) - Computadores Remote-processing RPC-2350 Manual do Utilizador
(83 páginas) - Computadores Remote-processing BASIC for the CX-10 Modbus Manual do Utilizador
(84 páginas) - Computadores Remote-processing BASIC 52 Manual do Utilizador
(163 páginas) - Computadores Remote-processing CAMBASIC Manual do Utilizador
(208 páginas)