Remote-processing RPC-210 Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Computadores Remote-processing RPC-210. Remote Processing RPC-210 User Manual Manual do Utilizador

RPC-210 USER'S MANUAL

REV 1

Page i
Copyr ight 2000 - Remote P rocessing Cor poration. All
rights reserved. However, any part of this document
may be reproduc ed with Remote Proce ssing cited as the
source.
The con tents of this manual and the specifications her ein
may change without notice.

TRADEMARKS

Intel is a copyright of Intel Corpora tion.
Windows, Windows 95, and Windows Terminal are
trademarks of M icrosoft Corporation.
Remote Processing and the triangle logos are a registered
trademark of Rem ote Processing Corpor ation.
Remote Processing® Corporation
79 75 E. Harvard Ave.
Denver, Co 802 31 USA
Tel: (303) 690 - 1588
Fax: (303) 690 - 1875
email: info@rp3. com
internet: www .rp3. com

NOTICE TO USER

The infor mation contained in this m anual is believed to
be correct. However, Remote Pr ocessing assumes no
responsibility for any o f the softwar e or cir cuits
described herein, conveys no license under any patent or
other r ight, a nd make no repr esentations that the circuits
are free from patent infringement. Rem ote Processing
makes no representation or warranty that such
applications will be suitable for the use specified without
further testing or modification. The user m ust make the
final determination as to fitness for a particular use.
Remote Pr ocessing Corporation' s general policy does not
recommend the use of its products in life support
applications where the failure or malfunction of a
component m ay directly threaten life or injury. It is a
Condition of Sale that the user of Remote Processing
products in life support applications assum es all the risk
of such use and indemn ifies Remote Pr ocessing against
all damages.

FCC NOTICE

The RPC-210 was not tested for EMI radiation. When
operated outside a suitable enclosure, the board and any
cables coming from the board w ill radiate harmful
signals which interfere with consumer and industrial
radio fr equencies. It is your r esponsibility to pr operly
shield the RPC-210 and cables coming from it to prevent
such interference.
P/N 1759
Revision: 1.3

Ficheiro PDF · ·

Imprimir

Imprimir documento

Partilha

Resumo do Conteúdo

Página 1 - FCC NOTICE

RPC-210 USER'S MANUAL REV 1 Page i Copyr ight 2000 - Remote Processing Corporation. All rights reserved. However, any part of this document may be…

Página 2 - TABLE OF CONTENTS

TABLE OF CONTENTS Page ii OVERVIEW SECTION 1 MANUAL ORGANIZATION 1 ADUC-812 INFORMATION 1 RTC INFORMATION 1 MANUAL CONVENTIONS 1 BASIC Statement types…

Página 3

TABLE OF CONTENTS Page iii COUNTER/TIMERS SECTION 8 COUNTER/ENCODER 1 J11 CONNECTOR PIN OUT 1 PULSE OUTPUTS 1 USING INTERRUPT 0 2 PULSE WIDTH &…

Página 4

DESCRIPTION OVERVIEW SECTION 1 The RPC-210 is a small embedded controller programmable in BASIC, C or assembly. This version includes a BASIC…

Página 5

26 Pin Connector Pin Out < xxx> Paired angle brackets are used to indicate a specific function key on your PC keyboard. For example < esc> means the…

Página 6

Figure 2-1 Connector Locations numbered 0 - 7, are available. The 8051 CPU series accesses RAM in 64K blocks. The RPC -210 bank switches RAM in 64K…

Página 7

INTRODUCTION SETUP AND OPERATION SECTION 2 The RPC -210 is ready to program as soon as you connect it to a PC and apply power. This section describes…

Página 8

Programs are saved in ASC II file form at. Terraterm m ay be used to insert small code changes without having to download the entire program.

Página 9

Figure 2-1 Power and Serial Progr amming Figure 2-2 Power input locations FIRST TIME OPERATION Become familiar with the locations of connectors before…

Página 10

Figure 2-3 W7 & W8 detail Power supply voltage P1 Terminal designation W7 & W8 positions +5V 5 W7[OFF], W8[OFF] + 6 to 16V E W7[OFF], W8[ON] 2.…

Página 11

Downloading a program requires transmitting an ASCII file. As you type in (or download) a line, RPBASIC-52 tokenizes that line. The time to do this…

Página 12

WHERE TO GO FROM HERE If you want to do this: Turn to Section Save a program 3 Run a program at power up or reset (Auto run) 3 Know m ore abo ut…

Página 13

Receiving a sign on message and can't enter characters. Check U9, pin 14 for at least -6 volts with the serial cable connected to the PC . W hen it is…

Página 14 - SAVING A PROGRAM

Figure 3-1 Flash EPROM location INTRODUCTION SAVING CODE AND DATA IN BASIC SECTION 3 Code and data are saved to external Flash at U6 only. Some of the…

Página 15 - HIDING A PROGRAM

WARNING: Be careful using the BSAVE command. RPBASIC resides at addresses 0 7000H, segment 0. If you overwrite any portion of this area, RPBASIC-52…

Página 16 - ASSEMBLY LANGUAGE INTERFACE

Using HIDE with RTC serial number Each real time clock (RTC) has a unique serial number associated with it. T his serial num ber may be used in…

Página 17 - COMMANDS

UPDATING OR REPLACING RPBASIC-52 program may be update d or replaced w hile in circuit. A current version of RPBASIC-52 for the RPC -210 is on the ap…

Página 18 - APPLICATION PROGRAMS

RPBASIC-52 Programming manual differences The limits for the commands listed below are different than shown in the RPBA SIC-52 m anual. Command…

Página 19 - COM0 SERIAL PORT

Figure 4-1 Serial Com munication Ports DESCRIPTION SERIAL PORTS SECTION 4 The RP C-210 has two ser ial ports that inter face to printers, terminals…

Página 20 - COM1 SERIAL PORT

Figure 4-2 COM 1 jumper locations Be aware that when continuously printing at this rate, interrupt processing overhead becomes significant. About 20%…

Página 21

Figure 4-3 RS-485 topology RS-422/485 OPERATING INFORMATION J6 is the RS-422/485 port. There are several things to consider when using this port.…

Página 22

Figure 4-4 Data packet RS-422/485 Termination network W10 enables the network terminator. When the RPC- 210 is the last physical unit on a network…

Página 23 - DISABLING CONTROL-C

Line 20 sets up ON COM$ to interrupt on a < CR> and branch to line 1000. Line 30 sets up this card' s address. Line 1010 checks to see if the received…

Página 24 - SPI PORT

SPI PORT Signals to communicate write to SPI compatible devices are available at J7. Relevant signals are shown below: J7 Pin Description 10 Chip…

Página 25 - RS-422/485 PORT PIN OUT

COMMANDS The following is a list of RPBASIC-52 commands used for serial I/O. These commands and functions are explained in the BASIC-52 Programm ing…

Página 26

Figure 5-1 RPBASIC-52 Memory Map INTRODUCTION RAM SECTION 5 512K of RAM is battery backed on the RPC-210. RAM size is determined by the IC in U 5, w…

Página 27

For this example, suppose there are 20 of these arrays that need to be set up. A program fragment is as follows: 100 STRING 400,20 Initialize 20…

Página 28

RPBASIC-52 Programming manual differences The limits for the commands listed below are different than shown in the RPBA SIC-52 m anual. Command RPBA…

Página 29

Figure 6-1 Digital Input - Output connectors INTRODUCTION DIGITAL LINES SECTION 6 Digital I/O lines ar e used to inter face with opto-module racks…

Página 30

Figure 6-2 Connector numbering scheme When an input line is brought low, that line will stay low until or unless pulled high through a 4.7K ohm, or 1…

Mostrar as 60 páginas
Página 31

J3 Port group Address A - Digital I/O & display (J4) 0A200H B - Digital I/O 0A201H C - Digital I/O 0A202H 82C55 configuration 0A203H The 82C55…

Página 32

to a more powerful processor such as the RPC- 320. There are no firm guidelines for what constitutes a “long” program. You may be able to process more…

Página 33

LINEB,0A307H,1 Inputs are read as follows: A = LINEB(0A400H) .AND. 0F0H USING ANALOG INPUTS Analog inputs may be used as digital inputs only. Simply…

Página 34

Pin out for J7 is shown below. J7 Pin No. Description Alternate Function 1 Real time clock interrupt source 2 Digital input, address 0A400H , bit 6 3…

Página 35 - BATTERY LIFE

INTRODUCTION REAL TIME CLOCK SECTION 7 A real time clock (RTC) incorporates an industry standard DS1287 with several enhanced features. Of note, these…

Página 36 - IDLE AND POWER DOWN MODES

STABILITY AND TEMPERATURE Real time clock's crystal initial tolerance is ±20 ppm. (Tolerance is specified as f/f.) This tolerance changes due to the…

Página 37 - PROGRAMMABLE INTERRUPTS

Other software type interrupts that require CPU processing such as ONTICK, ON LINE, ON COUNT, or ON KEYPAD are NOT active. IDLE 1 will work with…

Página 38 - PULSE OUTPUTS

Figure 8-1 INTRODUCTION COUNTER/TIMERS SECTION 8 There is one counter input and two pulse ouputs available on the RPC-210. C ounter input consists of…

Página 39 - MEASUREMENT

Figure 8-2 Pulse Width Measurement USING INTERRUPT 0 Interrupt 0 (INT 0) may be used for COM 1 serial communications. You cannot simultaneously use…

Página 40

Figure 8-3 Fr equency Measurem ent Program COUNT5A.BAS is a multi-tasking version of the frequency counter. It monitors the gating signal using ON…

Página 41 - EXTERNAL INTERRUPTS SECTION 9

EXTERNAL INTERRUPTS SECTION 9 Page 9-1 Figure 9-1 Interrupt inputs at Connectors INTRODUCTION EXTERNAL INTERRUPTS SECTION 9 External CPU interrupt INT…

Página 42

EXTERNAL INTERRUPTS SECTION 9 Page 9-2 Line 10 sets up the operating system to process interrupt 0. Lines 20 and 30 increment a counter used by the…

Página 43

Figure 10-1 Analog IO Connector and Jumpers INTRODUCTION ANALOG I/O SECTION 10 There are eight single ended analog to digital (A-D) input channels and…

Página 44

When I/O range is 5V max., set W12[1-2]. If the I/O range is 2.5V max. , set W12[2-3]. When W 12 is set to [1-2], a higher, but noisier supply voltage…

Página 45

A problem with offset and gain errors is that, at the extreme ranges, readings are probably unreliable. The upper and lower 100 mV should be deemed as…

Página 46

K = 200 / 4095 K = .0488 The result is in PSI w hen used as follows: 1000 B = .0488*AIN(0) The constant can be stored in RAM or Flash memor y. This “…

Página 47

Figure 10-2 5V Analog IO calibration you should use the 2.5V range instead. To calibrate or otherwise adjust the reference, connect volt meter ground…

Página 48

Gener ally, y ou have a fe w milli-am ps for your circ uit. You may be able to get more than this in your circumstance. Unfortunately, the only way to…

Página 49 - WRITING TO THE DISPLAY

Figure 11-1 Keypad and Display Connectors INTRODUCTION DISPLAY PORT SECTION 11 Port J4 supports 4 x 20 and 4 x 40 character LC displays. Eight lines…

Página 50 - CONTRAST/ANGLE ADJUSTMENT

Next, display type is set using the CONFIG DISPLAY command. Functional display types are 0 for the 4 x 40 character display and 1 for the 4 x 20.…

Página 51 - DEMONSTRATION PROGRAMS

DISPLAY CONNECTOR PIN OUT The display port uses port A of the 82C55 for data and control. The table below lists a pin number and its intended…

Página 52 - EXTERNAL POWER

EXPANSION PORT & POWER BASIC SECTION 12 Page 12-1 Figure 12-1 Power input and Expansion Port INTRODUCTION EXPANSION PORT & POWER SECTION 12 Expansion…

Página 53 - Expansion Port Pin Out

EXPANSION PORT & POWER BASIC SECTION 12 Page 12-2 No heat sink is necessary if power( P (MAX ) ) is less than 1. 7W and the board operate s at 25°C. A…

Página 54 - USING J7 FOR I/O

ACCESSING I/O BASIC SECTION 13 Page 13-1 INTRODUCTION ACCESSING I/O SECTION 13 I/O on the RPC-210 is defined here as devices that are not memory.…

Página 55 - RESOURCES SECTION 14

RESOURCES SECTION 14 Page 14-1 INTRODUCTIONRESOURCES SECTION 14 The RPC-210 can be used in a number of applications. We provide comm on accessories.…

Página 56

RESOURCES SECTION 14 Page 14-2 Haydon Switch & Instrument Inc. Stepper motors and drivers. 203 756 7441 www. hsi-inc.com OPTO modules The MPS-XX…

Página 57

BASIC COMMAND CHANGES SECTION 15 Page 15-1 Some commands listed in “RPBASIC-52 Software Manual” have different syntax or limits on the RPC-210.…

Página 58 - SHOCK AND VIBRATION

CPU Analog Devices ADU C812 operating at 11.0592 MHZ TECHNICAL SPECIFICATIONS SECTION 16 Power Supply Inputs: 5 ±0.25VDC or 6-16V Current: 150 ma…

Página 59 - MOUNTING TO A MOTHER BOARD

between the battery and IC under it to keep the battery from rocking. Bear in mind that the clock and RAM draw micro-amps of current. Any conduction…

Página 60 - BOARD DIMENSION

Figure 16-1 Figure 16-2 Mounting hole locations CONNECTOR POSITION Connectors shown above are on 0.1" spacing. Dimensions ar e in inches. BOARD…

Perguntas sobre Remote-processing RPC-210

Ainda não há perguntas sobre este manual. Faça a primeira.

Fazer uma pergunta

Respondemos a partir do manual e indicamos a página. A pergunta é publicada no site depois de verificada.

Todas as perguntas e respostas ›

Manuais e produtos relacionados com Computadores Remote-processing RPC-210